{"id":1628,"date":"2018-01-31T06:02:52","date_gmt":"2018-01-31T06:02:52","guid":{"rendered":"http:\/\/10.0.1.201\/mech\/?page_id=1628"},"modified":"2021-08-15T10:16:39","modified_gmt":"2021-08-15T10:16:39","slug":"consultancy","status":"publish","type":"page","link":"https:\/\/www.vrsiddhartha.ac.in\/me\/consultancy\/","title":{"rendered":"Consultancy"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column]<div class=\"rt-vc-text-title  style2\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Consultancy<\/h2>\n\t\t\t<\/div>[\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tour][vc_tta_section title=&#8221;Direct Thermal Conductivity&#8221; tab_id=&#8221;1628656230803-204dd767-b7ca&#8221;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Direct Thermal Conductivity<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong> Measurement of thermal conductivity of materials<\/div>\n<div><strong>Make:<\/strong> TA Instruments, Model: DTC 300<\/div>\n<div><strong>Specifications: <\/strong>Thermal conductivity range: 0.1 to 40 W\/mK<\/div>\n<div><strong>Temperature Range:<\/strong> 20<sup> o<\/sup>C\u00a0 to 300 <sup>o<\/sup>C<\/div>\n<div><strong>Standard:<\/strong> \u00a0ASTM E1350<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2858 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/1_Thermal-Conductivity.jpg\" alt=\"\" width=\"1293\" height=\"743\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/1_Thermal-Conductivity.jpg 1293w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/1_Thermal-Conductivity-300x172.jpg 300w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/1_Thermal-Conductivity-768x441.jpg 768w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/1_Thermal-Conductivity-1024x588.jpg 1024w\" sizes=\"auto, (max-width: 1293px) 100vw, 1293px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Impact Tester&#8221; tab_id=&#8221;1628656230811-7d231dce-8158&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Impact Tester<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong> Impact strength of polymer composite materials<\/div>\n<div><strong>Make:<\/strong> M\/s. International Equipment\u2019s., Mumbai<\/div>\n<div><strong>Energy Max:<\/strong> 22 J<\/div>\n<div><strong>Standard:<\/strong> \u00a0ASTM D256<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2867 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/2_good_Impacttester.jpg\" alt=\"\" width=\"480\" height=\"592\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/2_good_Impacttester.jpg 480w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/2_good_Impacttester-243x300.jpg 243w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Wear Test Rig&#8221; tab_id=&#8221;1628659425126-b74cc316-d708&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Wear Test Rig<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong>\u00a0 Wear and frictional force of materials<\/div>\n<div>Ducom Instruments, Bangalore<\/div>\n<div><strong>Specifications:<\/strong><\/div>\n<div>Load:\u00a0 200N<\/div>\n<div>Pin Heating Temp: 400<sup>o<\/sup>C<\/div>\n<div>Disc Size : 165 X 8 mm<\/div>\n<div>Pin holders: 3, 4, 6, 8, 10 &amp; 12 mm<\/div>\n<div><strong>Standard: <\/strong>ASTM G99<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2871 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/3_Wear-Test-Rig.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/3_Wear-Test-Rig.jpg 800w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/3_Wear-Test-Rig-300x169.jpg 300w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/3_Wear-Test-Rig-768x432.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Tensometer&#8221; tab_id=&#8221;1628659450027-ca21e6ca-cc1c&#8221;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Tensometer<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong> \u00a0Tensile and flexural properties of polymer composite materials<\/div>\n<div><strong>Specifications:<\/strong><\/div>\n<div>Load cell: 20 kN<\/div>\n<div>Elongation: 0 to 500 mm with least count: 0.1mm<\/div>\n<div>Test speed: 0.2 mm\/min to 500mm\/min<\/div>\n<div>\u00a0<strong>Standard<\/strong>: Tensile <strong>&#8211;<\/strong>ASTM D638M \u00a0, \u00a0\u00a0\u00a0\u00a0Flexural &#8211; ASTM D 790M<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2875 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/4_TENSOMETER.jpg\" alt=\"\" width=\"800\" height=\"451\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/4_TENSOMETER.jpg 800w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/4_TENSOMETER-300x169.jpg 300w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/4_TENSOMETER-768x433.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Sonicator&#8221; tab_id=&#8221;1628659485797-28945684-9178&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Sonicator<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div>Purpose: Mixing of Nano particles with liquids<\/div>\n<div>Make: TRANS-O-SONIC, Mumbai<\/div>\n<div>Frequency 30 kHz<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2878 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/5_Sonicator.jpg\" alt=\"\" width=\"800\" height=\"451\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/5_Sonicator.jpg 800w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/5_Sonicator-300x169.jpg 300w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/5_Sonicator-768x433.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Dilatometer&#8221; tab_id=&#8221;1628659502134-3866ccf7-75b1&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Dilatometer<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong> Measurement of thermal expansion of materials<\/div>\n<div>Supplied by VB Ceramic Consultant, Chennai<\/div>\n<div>Temperature: Up to 1000 \u00b0C<\/div>\n<div>Accuracy: 0.1 \u00b5m<\/div>\n<div><\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2880 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/6_Dilatometer.jpg\" alt=\"\" width=\"800\" height=\"543\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/6_Dilatometer.jpg 800w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/6_Dilatometer-300x204.jpg 300w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/6_Dilatometer-768x521.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Durometer&#8221; tab_id=&#8221;1628659585030-9fa0110a-2384&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Durometer (Shore D Hardness Tester)<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong>\u00a0 Hardness of polymer composite materials<\/div>\n<div>Range:\u00a0 0 to 100 HD<\/div>\n<div>Standard:\u00a0 ASTM D2240<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2883 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/7_-Durometer.png\" alt=\"\" width=\"578\" height=\"480\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/7_-Durometer.png 578w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/7_-Durometer-300x249.png 300w\" sizes=\"auto, (max-width: 578px) 100vw, 578px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Computer Integrated Optical Microscope&#8221; tab_id=&#8221;1628659633133-22f9c740-7b04&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Computer Integrated Optical Microscope<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2886 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/8_Comp-Integrated-Optical-Microscope_IMG-20200616-WA0084.jpg\" alt=\"\" width=\"640\" height=\"480\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/8_Comp-Integrated-Optical-Microscope_IMG-20200616-WA0084.jpg 640w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/8_Comp-Integrated-Optical-Microscope_IMG-20200616-WA0084-300x225.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p>Our Metallurgical Microscope meets wide-variety of analysis applications, from a routine inspection to sophisticated analysis of weld metal study. We have Metallurgical Image Analysis Software with Accuracy, repeatability and authentic results. Most advance &amp; user friendly and User defined macro.<br \/>\n1. Batch runs facilities available.<br \/>\n2. 1:1 magnification and equivalent field of view Database.<br \/>\n3. Online image processing.<br \/>\n4. Any type of customization possible with our software.<br \/>\n5. Calibration traceable to NABL standard.<br \/>\n6. Color Images Processing.<br \/>\n7. Phase analysis based on color and shapes.<br \/>\n8. Image of any size can be processed.<br \/>\n9. Capture speed one image \/ second.<br \/>\n10. Online capture and simultaneous processing of many no of images at very short duration.<br \/>\n11. Data and images can be transferred to both word and excel format<br \/>\n12. Micron Marker incorporated in the image.<\/p>\n<h2 class=\"rtin-title\"><\/h2>\n<table width=\"631\">\n<tbody>\n<tr>\n<td width=\"180\">Optical System<\/td>\n<td width=\"451\">Plan Achromatic, Antireflection coated Optical system<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Stand<\/td>\n<td width=\"451\">Sturdy build inverted Microscope design<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Observation Head<\/td>\n<td width=\"451\">High Transmission sidentopf Trinocular<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Eye pieces<\/strong><\/td>\n<td width=\"451\"><strong>WF 10x (Paired)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Plan Objectives (Anti Fungus)<\/strong><\/td>\n<td width=\"451\"><strong>Multilayer, Anti reflection coated plan metallurgical<\/strong><\/p>\n<p><strong>objectives from Kyowa optics Japan consists of PLM 5X, PLM10x, PLM 20x and PLM 50x<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Focusing<\/td>\n<td width=\"451\">Low Position coaxial coarse and fine adjustment on ball track movement fro-greater reliability. Coarse motion range 35mm.<\/p>\n<p>Fine Focus range 1.4mm<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Nosepiece<\/td>\n<td width=\"451\">Quadruple ball bearing nosepiece for perfect alignment<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Stage<\/td>\n<td width=\"451\">Coaxial graduated mechanical stage 180 mm x 150mm with z-<\/p>\n<p>y travel 75 mm x 50 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Incident<\/td>\n<td width=\"451\">Built in Koehler\u2019s incident illuminations with 6v \/20w<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Illumination<\/td>\n<td width=\"451\">Halogen Lamp, field and aperture diaphragm, also having<\/p>\n<p>filters slot for yellow and green filters.<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Magnification<\/strong><\/td>\n<td width=\"451\"><strong>50X\u00a0 to\u00a0 500X<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Polarizing Attachment<\/td>\n<td width=\"451\">Incident Polarizing Attachment for examination of inclusions,<\/p>\n<p>bubbles, etching &amp; scratches on materials with bire fringance.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Variable Compression Ratio CI Engine&#8221; tab_id=&#8221;1628659745308-9afca246-0e08&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Variable Compression<\/h2>\n\t\t\t\t<p class=\"rtin-content\">Purpose: Performance and emission characteristics of Bio diesel<br \/>\nSpecifications:<br \/>\nKirloskar, 4 Stroke 1 Cylinder Water Cooled Diesel Engine<br \/>\nRated Power: 3.7KW (5HP)<br \/>\nBore Diameter: 80mm<br \/>\nStroke Length: 562cc<br \/>\nCompression Ratio: 12:1 to 20:1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2929 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/9.2_VCR-Engine.jpg\" alt=\"\" width=\"640\" height=\"480\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/9.2_VCR-Engine.jpg 640w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/9.2_VCR-Engine-300x225.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Coordinate Measuring Machine&#8221; tab_id=&#8221;1628659846878-5fa1890f-bc38&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">COORDINATE MEASURING MACHINE (CMM)<\/h2>\n\t\t\t\t<p class=\"rtin-content\">Purpose: Measurement of geometric characteristics of an object<br \/>\nMake &amp; Model : Accurate India, Spectra<br \/>\nSpecifications: Operation: CNC<br \/>\nOverall Machine Dimensions (LxWxH): 1500 x 1445 x 2350 mm<br \/>\nMeasuring Range: X axis: 500mm, Y axis: 600mm, Z axis: 400mm<br \/>\nMax. Permissible error: 2.2 micron<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2930 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/10_Coordinate-Measuring-Machine.png\" alt=\"\" width=\"518\" height=\"632\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/10_Coordinate-Measuring-Machine.png 518w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/10_Coordinate-Measuring-Machine-246x300.png 246w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><\/p>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Profile Projector&#8221; tab_id=&#8221;1628659894468-db88009a-4640&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Profile Projector<\/h2>\n\t\t\t\t<p class=\"rtin-content\">Purpose: Linear and Angular Measurement<br \/>\nMake: OPTOMECH, Model: 300 TE Table Top Vertical Profile Projector<br \/>\nSpecifications: Magnification: 20X<br \/>\nWork Piece Capacity: 1) Load Capacity: 20 kgs<br \/>\n2) Max Diameter: 150 mm<br \/>\nAccuracy: +\/- 0.1%<br \/>\nLeast Count: 0.001 and 2min<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2932 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/Profile-Projector.jpg\" alt=\"\" width=\"640\" height=\"480\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/Profile-Projector.jpg 640w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/Profile-Projector-300x225.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n\t\t<\/div>[\/vc_tta_section][vc_tta_section title=&#8221;Surface Tester&#8221; tab_id=&#8221;1628659911901-36e39b5f-0278&#8243;]<div class=\"rt-vc-text-title  style1\" style=\"\">\n\t\t\t<h2 class=\"rtin-title\">Surface Tester<\/h2>\n\t\t\t\t<p class=\"rtin-content\"><\/p>\n<div><strong>Purpose:<\/strong> Surface roughness measurement<\/div>\n<div><strong>Make:<\/strong> MITUTOYO Stylus type, Model: SJ210,<\/div>\n<div><strong>Specifications: <\/strong>Measuring Speed : Measuring: 0.25 mm\/s, 0.5 mm\/s, 0.75 mm\/s Returning: 1 mm\/s<\/div>\n<div>Measuring Force\/Stylus Tip: 0.75 mN Type: 0.75 mN \/ 2 \u00b5m R 60\u00b0 4 mN Type: 4 mN \/ 5 \u00b5m R 90\u00b0<\/div>\n<div><strong>Analysis Graphs:<\/strong> Bearing area curve, Amplitude distribution curve<\/div>\n<div><strong>Sampling Length:<\/strong> 0.08mm, 0.25 mm, 0.8 mm, 2.5 mma<\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2937 size-full\" src=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/12_Surface-Tester-e1629022581361.jpg\" alt=\"\" width=\"601\" height=\"272\" srcset=\"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/12_Surface-Tester-e1629022581361.jpg 601w, https:\/\/www.vrsiddhartha.ac.in\/me\/wp-content\/uploads\/2021\/08\/12_Surface-Tester-e1629022581361-300x136.jpg 300w\" sizes=\"auto, (max-width: 601px) 100vw, 601px\" \/><\/div>\n<p><\/p>\n\t\t<\/div>[\/vc_tta_section][\/vc_tta_tour][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tour][vc_tta_section title=&#8221;Direct Thermal Conductivity&#8221; tab_id=&#8221;1628656230803-204dd767-b7ca&#8221;][\/vc_tta_section][vc_tta_section title=&#8221;Impact Tester&#8221; tab_id=&#8221;1628656230811-7d231dce-8158&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Wear Test Rig&#8221; tab_id=&#8221;1628659425126-b74cc316-d708&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Tensometer&#8221; tab_id=&#8221;1628659450027-ca21e6ca-cc1c&#8221;][\/vc_tta_section][vc_tta_section title=&#8221;Sonicator&#8221; tab_id=&#8221;1628659485797-28945684-9178&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Dilatometer&#8221; tab_id=&#8221;1628659502134-3866ccf7-75b1&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Durometer&#8221; tab_id=&#8221;1628659585030-9fa0110a-2384&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Computer Integrated Optical Microscope&#8221; tab_id=&#8221;1628659633133-22f9c740-7b04&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Variable Compression Ratio CI Engine&#8221; tab_id=&#8221;1628659745308-9afca246-0e08&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Coordinate Measuring Machine&#8221; tab_id=&#8221;1628659846878-5fa1890f-bc38&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Profile Projector&#8221; tab_id=&#8221;1628659894468-db88009a-4640&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;Surface Tester&#8221; tab_id=&#8221;1628659911901-36e39b5f-0278&#8243;][\/vc_tta_section][\/vc_tta_tour][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1628","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/pages\/1628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/comments?post=1628"}],"version-history":[{"count":41,"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/pages\/1628\/revisions"}],"predecessor-version":[{"id":2945,"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/pages\/1628\/revisions\/2945"}],"wp:attachment":[{"href":"https:\/\/www.vrsiddhartha.ac.in\/me\/wp-json\/wp\/v2\/media?parent=1628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}